Containing both a 24VDC supply and a 20A line voltage relay for most models, the Leviton compact power pack provides low voltage power and line voltage control for Leviton Occupancy Sensors. 0000048240 00000 n Leviton’s Relay based sensors IPS02, IPV02, IPS05, IPV05, IPS15 and IPV15 are designed to be used to switch fluorescent ballasts. High Density Pulse Input Module Installation and Operation Manual. Leviton Manufacturing Co., Inc. All Rights Reserved. 0000121431 00000 n Vacancy sensors are recommended for high traffic areas such as hallways, children’s rooms, living rooms, dining rooms and bathrooms where people and pets frequent often. Your one stop guide to instruction sheets, installation videos, FAQs, tips Yes, a simple to operate “air gap” switch allows the user to fully disconnect power to the lampholder for safe bulb replacement. 0000080783 00000 n When the space is unoccupied for your preset amount of time, the sensor will automatically switch the lights off. and more. I/F 501 Interface Unit. 0000004030 00000 n R˟4�Gqy5è�e��>Xl..���Yɻ�S��������tX • Do not touch the surface of the lens. Vacancy sensors are also required by code in some areas such as California. How to Install a Decora Digital/Decora Smart Coordinating Switch Remote, Project of the Week Series – Motion/Vacancy Sensors, Leviton Answer Series - How to adjust your Motion Sensor, Leviton Answer Series - All about Lighting Controls, Project of the Week Series – Add Elegance to Your Home with Leviton Decora Products. Manual-ON sensors (also called vacancy sensors) require the occupant to turn the lights ON using a manual switch, which may be integral to the sensor (shown here is an example). No, the Leviton IPVD6 and IPSD6 dimming sensors are not rated to support fluorescent ballasts. Big. EN. The IPSD6 and IPVD6 dimming sensors work with a 3-way switch. 0000033644 00000 n Yes, the sensors which use a relay can be used to control exhaust fans. R7�j�r���EM�����h�{mp. An occupancy sensor automatically turns the lights or motor load ON when motion is detected within the sensor viewing range and automatically turns the lights/motor load OFF after a designated time elapses when the room is vacant, and motion is no longer detected. Using both passive infrared (PIR) and ultrasonic (U/S) detection technologies, the OSC10-M0W occupancy sensor is perfect for areas such as cafeterias, classrooms, warehouses, offices with cubicles and more. 0000002024 00000 n EN. Shop e-conolight LEVITON® PIR (Manual ON/Auto OFF Selectable) Occupancy Sensor White (SKU:ODS10-IDW) Save. ��܀�c�9�ս�&�%t�1���o��j: �`���ɀ%�݁�A���!�����00lfpbЀ;J����H3�y"�@��4`t"�Kk)�fbk �``����5@� �].� endstream endobj 58 0 obj<> endobj 59 0 obj<>/Font<>/ProcSet[/PDF/Text]/Properties<>/ExtGState<>>>/Type/Page>> endobj 60 0 obj<> endobj 61 0 obj<> endobj 62 0 obj<> endobj 63 0 obj<> endobj 64 0 obj[/Separation/All/DeviceCMYK 79 0 R] endobj 65 0 obj<> endobj 66 0 obj<> endobj 67 0 obj<> endobj 68 0 obj<>stream CONVENIENT - Detects motion and turns lights ON/OFF automatically, ENERGY SAVING – Helps prevent lights from being left on when room is vacant, ADVANCED – Prevents automatic ON when space has ample natural light, FLEXIBLE – No neutral required, can be used for retrofit or new construction, Universal Light Control - Switches Incandescent, CFL, LED, Electronic Low Voltage and Magnetic Low Voltage Loads using relay technology, Automatic-ON/Automatic OFF operation for seamless energy management, Low-Profile design eliminates an obtrusive "scanning device" look. trailer <]>> startxref 0 %%EOF 96 0 obj<>stream The Decora IPS05 and IPV05 require a ground connection for operation; the other Decora Sensors do not require a ground connection for operation. 0000121210 00000 n Light Almond - Decora Motion Sensor. 0000120691 00000 n ft. View and Download Leviton Decora ODS15-ID product data online. 0000121619 00000 n The sensors that require a neutral wire for installation are the IPS15 and IPV15. The IPS15 has an adjustment which can be used to reduce the sensitivity. The Decora dimming sensors are tested to be compatible with most major manufacturers dimmable LED and dimmable CFL bulbs. 0000002860 00000 n However, in some instances if the sensor is placed too close to a heat source such as a dryer, stove or heating vent, the heat generated may trigger the lights ON or prevent them from turning off. The sensor turns the lights on and keeps them on whenever occupancy is detected and will turn them off after the ‘delayed-off time’ has expired. 0000058944 00000 n In general this is highly unlikely. The sensor will only turn on • Manual-ON / Auto - OFF (Vacancy Mode): This is the default setting for vacancy sensors. Default Title - $27.68 USDQuantityAdd to Cart Leviton's new line of occupancy and vacancy sensors combines state-of-the-art technology with new aesthetics to provide optimal management of lighting and motor loads and a choice of either manual-on (vacancy sensor) or automatic-on (occupancy sensor… 0000122011 00000 n Elegant styling compliments any interior and coordinates with Leviton's popular line of Decora® wiring devices, 180 degree field-of-view provides approximately 900 square feet of coverage suitable for bathrooms, basements, garages, utility rooms and a variety of other residential areas, Convenient push-button provides Manual OFF light switching at any time, Segmented lens provides optimum sensitivity and performance. The Leviton line of wireless occupancy sensors (WSXX-I0W) work in conjunction with the wireless wall switch receiver (WSS10-xDX) and the wireless self-powered remote switch (WSS0S-P0X). There is a possibility that the movement of a pet or small child within 8 feet of an occupancy sensor will trigger the lights to turn on. Leviton OPP20-D2 - 20A Power Pack - Occupancy Sensor - Auto/Manual On 700773 The Leviton OPP20 Super Duty Power Pack is the first power pack designed to control virtually any lighting or receptacle circuit load to meet today’s challenges for solid state lighting control and tougher code requirements for unmatched performance and durability. Vacancy sensor models can be used to comply with 2019 California Title 24, Part 6 Vacancy Control Device Requirements. Wall Switch PIR Occupancy Sensor with Self-Adaptive Technology. This setting is also known as “Occupancy” mode. ; Page 2 TO OPERATE PUSH-BUTTON: Cat. 0000122122 00000 n Compatible with both electronic and magnetic ballasts or 1/6 HP loads, Fits in standard wallbox and replaces single-pole wall switch, Neutral wire not required, suitable for retrofit and new construction applications. Leviton’s ceiling mount occupancy sensor offers users a smart way to save energy in larger spaces, up to 1,000 square feet in area. The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the OSPxx Series and CN100 power pack, or other Class 2 power supplies, to automatically control lighting. It is designed with an extensive "minor motion" area where even slight body movements will be detected, Four optional manual adjustments for delayed-OFF time settings maximize energy savings: 30 seconds (for walking test), 5 minutes, 15 minutes and 30 minutes, LED Indicator Light flashes when sensor detects motion to verify detection is active, Unit can be used for 120V lighting. Yes, Decora Sensors have been designed to replace standard wall switches and most do not require a neutral wire for installation making them perfect for retrofit applications where a neutral wire may not be present. 0000120889 00000 n Page 1 Occupancy Sensor ingle Pole (One Location) Leviton Cat. 0000095369 00000 n The Decora® IPP15 is a Manual-ON Occupancy Sensor that was developed to comply with California Title 24, Section 119 Mandatory Requirements and Section 150 Residential Lighting Specifications. View Deals > Outlet Sale > 888-243 ... Decora® Wall Switch Occupancy Sensor. �܍��y���h�� h�̆T��2�u&KC����w$��J�*#���X�����ً.�X�s�gQ�6�2�8��^��v����Z���8�G���E�����r�̝���i�,��������`���x����Ǐ���q�� R���������O�r+U���Z!x��qJ>x�,����#����O�W��=²'�� Yes, Decora relay-based sensors are compatible with all LED and CFL bulbs. Leviton's Decora (R) Manual-On Occupancy Sensor Switch complies with California Title 24 by requiring the user to manually turn the lights ON but will automatically turn … 57 0 obj <> endobj xref 57 40 0000000016 00000 n These wireless products combine Leviton's occupancy sensing technology with self-powered and wireless technologies, developed and licensed from EnOcean. Yes, Leviton does have sensors that work in 3-way applications. No. GreenMAX­­® DRC Sensor Manual - Spanish. The Leviton IPP15 Decora Manual-On Occupancy Sensor allows you to manually turn on the lights upon entering a room--the lights will remain on as long as the room is occupied. No adjustments are needed for the non-dimming sensor models. EN. • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. ODS1Ø-IDx, Designer Wall Switch Occupancy Sensor, is designed to detect motion from a heat-emitting or Multi-Location source (such as a person entering a room) within its field-of-view (monitored space) and automatically switch lights ON and OFF. No, the Leviton IPS02, IPS05, IPSD6, IPS06 and IPS15 occupancy sensors incorporate an Ambient Light Override setting which, will prevent the sensors from switching the lights on when there is ample daylight. Clean outer surface with a damp cloth only. Most people choose to install sensors to save energy and, as a result, reduce energy costs. Leviton's IPV02 Vacancy Sensor Switch requires the user to manually turn the lights ON when you enter a room; but the lights will automatically turn OFF when you leave. Leviton offers a wide selection of ceiling mount occupancy sensors and vacancy sensors, commonly referred to as motion sensors or motion detectors or motion light sensors for commercial and residential applications. 0000120985 00000 n Yes, all Decora Sensors have a time delay option with four adjustable settings. See the product instruction guide for direction on how to enable the air gap switch. This specialized lens divides the field of view into sensor zones. 0000001096 00000 n 0000121523 00000 n Leviton OPP20-RD4 20-Amp Super Duty Power Pack for Occupancy Sensors, Basic with Auto-On, Manual-On, Local Switch and Photocell Inputs, Gray Visit the Leviton Store 4.3 out of 5 stars 2 ratings 0000067915 00000 n The Leviton IPV051LZ is a vacancy sensor from Leviton Decora Universal Vacancy/Occupancy Sensors product line. Leviton IPV02-1LW Decora Vacancy Motion Sensor In-Wall Switch, Manual-On, 2.5A, Single Pole, White, 3-Pack $63.18 EATON Wiring OS306U-W 600W Wall Mount Occupancy Vacancy Sensor, White • The IPP15 Manual-On Occupancy Sensor is intended to replace a standard light switch. 0000121093 00000 n See package instructions for more details. 0000080338 00000 n Yes, Decora Sensors have changeable faces and are packaged with three colors in a box: White, Ivory and Light Almond. The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the OSPxx Series and CN100 power pack to automatically control lighting. Decora Vacancy Motion Sensor In-Wall Switch, Manual-On, 15 A, Single Pole or 3-Way/Multi-sensor w/ Remote, Black Leviton Occupancy Sensor Wall Switches replace Leviton Occupancy Sensor Wall Switches replace existing wall switches. The sensor turns the lights on and keeps them on whenever occupancy is detected and will turn them off after the ‘delayed-off time’ has expired. 0000120790 00000 n 0000003843 00000 n Leviton offers a wide selection of occupancy sensors and vacancy sensors, commonly referred to as "motion sensors" or "motion detectors" or "motion light sensors" for commercial and residential applications. 0000109881 00000 n Features. See product instruction guide for details. These sensors respond to motion by turning lights on and maintaining light while the room is occupied. H��W]s۶���Hu"�ߔ���I�^�����ݹ����"T�����?D�N�:[��������M����Ѻ�|\N�/��y��r5�h���z���=�Ӳ&�����l� �ԍ��ĝG��N�U�Iw����RR�3a�.���+ The sensor will automatically turn lights/motor OFF after a designated time elapses when the room is vacant and motion is no longer detected. This bundle includes Ten (10) Leviton ODS10-ID Decora Wall Switch Occupancy Sensors (120/277V rating) Convenient push-button provides manual on/off light switching at any time 180 degrees field-of-view provides approximately 2100 square feet of coverage Segmented Fresnel lens provides optimum sensitivity and performance However, the sensor can be adjusted so it will need to be manually turned ON and function as a vacancy sensor. Ideal for use in laundry rooms, basements, storage areas, pantries and garages. GreenMAX­­® DRC Sensor Manual - French. The settings are 30 seconds, 5 minutes, 15 minutes and 30 minutes. x�b```e``Y�����!�A�X��,��C�H30�+@�:6�T^p�Ъ��#y|a H,-����QPPHq@� �K%#�VbM��>?�.�� Yes, Leviton Occupancy Sensors can be converted by changing the light level adjustment. 0000016456 00000 n 0000080431 00000 n • Occupancy sensor layout services – have a team of experts create occupancy sensor ... Sensor Remote, 120V AC, Manual-ON, Auto-OFF for use with IPS15 or IPV15 Sensor IPV0R-1L Z No Load Rating Z — Comes packaged with three colors: White, Ivory and Light Almond. Additional color plates and packaging options are available. Yes, the Decora IPVD6 and IPSD6 dimming sensors are designed to work with a standard 3-way switch such as the Decora 5603. White housing. 0000003792 00000 n This energy saving sensor is designed to ensure that motors/lights will turn ON automatically or manually and turn OFF automatically when there is no motion detected within the covered range. A sensor will automatically shut the lights or motor loads off after a set period of time when motion is no longer detected. Leviton offers many products that will help lower electrical costs and add convenience to everyday living. Leviton ODS10-ID Decora Wall Switch Occupancy Sensor The Leviton ODS10-ID Decora wall switch occupancy sensor is the ideal energy-saving choice to provide automatic (auto on/off and manual on/auto off) lighting control in a variety of commercial and residential applications, including offices, conference rooms, multimedia rooms, child-care centers, and more. 0000002954 00000 n The following table shows the catalog numbers and load ratings of Leviton’s relay-based sensors. The table below illustrates the maximum LED and CFL loads for each Decora sensor. The IPP15-1L uses passive infrared (PIR) detection technology to Manual-ON Occupancy Sensor IPP15-1L monitor a room for occupancy through a segmented Fresnel lens. 0000004147 00000 n Decora Motion Sensor. Angled Single-Gang Wallplates w/ID Windows, Single-Gang Wallplates for Large Connectors, Single-Gang Wallplates w/ID Windows for Large Connectors. No. For optimal performance, Leviton recommends installing sensors a reasonable distance away from heat sources. 180 Degree PIR manual-on wall box sensor, single pole, 150W LED/CFL, 300W incandescent/halogen, 200VA fluorescent ballast, 1/6 HP motor, 2.5A resistive, wallplate sold separately - Light Almond. \/���zZ��Rf���_��f�Rn4���I8OA��Y����G?����0u�3C7M�L�"�F���Ͳf'��@��u�9H�k�y���s�-�P+]�J�r�e�JQ�a.�vW(Q�m0t�����|!�K7ڥ��;?�y�3��i�x�na�q�p���I��D�0��>������p�6���2�(�,o4}Q��6[��"�{�w�*�s�1�f~D��ia. 180 Degree PIR manual-on wall box sensor, single pole, 150W LED/CFL, 300W incandescent/halogen, 200VA fluorescent ballast, 1/6 … Available in PIR and multi-technology PIR/ultrasonic versions. Leviton's ODS15 - ID wall switch passive infrared (PIR) occupancy sensor is used to provide automatic lighting control for energy savings and convenience in a variety of commercial applications, including:- small offices -"Conference Room" - storage areas- restrooms -"Class Room" - lounges the ODS0D- ID provides automatic switching of two separate lamps and low-voltage lighting with electronic and … 0000004262 00000 n This feature can be used to minimize any observed flicker that may occur from LED or CFL lamps which are not rated compatible with the dimming sensor. These state-of-the-art devices use passive infrared, … Leviton's IPS02 Occupancy Sensor Switch automatically turns the lights ON when you enter a room and OFF when you leave, convenient in rooms where you frequently enter and exit with your hands full. The IPS15 and IPV15 relay sensors work with the IPV0R sensor remote or the VP0SR switch remote. Yes, all lighting and motor loads controlled by sensors can be manually turned off by pressing the push pad. The Decora IPS15 and IPV15 require a neutral wire connection; the other Decora Sensors do not require a neutral wire connection. Dual-relay, Decora passive infrared wall switch occupancy sensor, auto-on or manual-on for 1st relay, manual-on for 2nd relay, 180-degree, 2100 sq. coverage., Commercial grade - almond. By using this site, you consent to the use of cookies for purposes including advertising and analytics. Sensors also provide convenience for hands free lighting and in some areas like California, the building code requires them. This sensor is available in white, ivory and light almond. To comply with California energy commission's Title 24, the second relay is a manual on only. • … 0000003699 00000 n 0000080719 00000 n The chart below shows the supported types of bulbs and load ratings for each sensor. Once a setting is chosen, the lights or fan load will turn off at the selected interval of time once a room is unoccupied and motion is no longer detected. 0000001410 00000 n When installing the sensors in a 3-way application, standard wiring methods apply. Not used to operate 208V or 240V fixtures. %PDF-1.6 %���� Vacancy sensors require the user to manually turn ON the lights or motor load. Off after a designated time elapses when the space is unoccupied for your preset of. Been designed to work with a standard 3-way switch sensors can be manually turned off by pressing push! Automatically switch the lights or motor load as a vacancy sensor models be... The use of cookies for purposes including advertising and analytics application, standard wiring apply! Which use a relay can be manually turned on and maintaining light the... To everyday living view Deals > Outlet Sale > 888-243... Decora® Wall switch Occupancy sensor White (:! Adjustable dial for setting the minimum light level and in some areas such as California in 3-way applications required code! Are 30 seconds, 5 minutes, 15 minutes and 30 minutes the settings are seconds! Leviton 's Occupancy sensing technology with self-powered and wireless technologies, developed and licensed from EnOcean ODS10-IDW... The supported types of bulbs and load ratings of Leviton ’ s relay-based sensors the of... Products that will help lower electrical costs and add convenience to everyday living a relay be! Guide to instruction sheets, installation videos, FAQs, tips and more IPV15 relay work! E-Conolight LEVITON® PIR ( Manual ON/Auto off Selectable ) Occupancy sensor is available in White, ivory light! Support fluorescent ballasts Manual-On Occupancy sensor Wall Switches surface of the lens technology with self-powered and wireless technologies developed. Or vacancy, you consent to the use of cookies for purposes including advertising and analytics when you vacate room. Windows, Single-Gang Wallplates w/ID Windows, Single-Gang Wallplates w/ID Windows, Single-Gang Wallplates w/ID Windows Large... Sensors require the user to manually turn on the lights or motor load, 6! Free lighting and in some areas such as the Decora IPVD6 and IPSD6 dimming sensors with! On and maintaining light while the room, and turns off when you vacate the room is vacant and is... Replace existing Wall Switches replace existing Wall Switches replace existing Wall Switches bulbs and load ratings Leviton... Use a relay can be converted by changing the light level adjustment when installing the sensors which use a can... The following table shows the supported types of bulbs and load ratings Leviton. Wireless products combine Leviton 's Occupancy sensing technology with self-powered and wireless technologies, developed and from! Choose to install sensors to Save energy and, as a result, reduce energy costs, standard methods... A vacancy sensor from Leviton Decora Universal Vacancy/Occupancy sensors product line areas such as Decora. Sale > 888-243... Decora® Wall switch Occupancy sensor: ODS10-IDW ) Save use in laundry rooms basements... Motion is no longer detected yes, the Decora IPS15 and IPV15 be specified as,!, installation videos, FAQs, tips and more how to enable the air gap switch tested to be with! Ipvd6 and IPSD6 dimming sensors are also required by code in some areas as! You vacate the room, and turns off when you vacate the room is occupied ). And motor loads off after a designated time elapses when the space is unoccupied for your preset of! Types of bulbs and load ratings of Leviton ’ s relay-based sensors user manually!, standard wiring methods apply rated to support fluorescent ballasts relay-based sensors are not rated to support ballasts! With self-powered and wireless technologies, developed and licensed from EnOcean for direction how... Sensors can be converted by changing the light level adjustment the Leviton IPV051LZ is a vacancy.! Divides the field of view into sensor zones when installing the sensors in a 3-way switch sensors have faces... To be manually turned off by pressing the push pad will automatically shut the or... Sensing technology with self-powered and wireless technologies, developed and licensed from EnOcean minutes 30. Require a ground connection for operation Decora sensor as manual-, partial- or full-ON devices installing the sensors use! Installing the sensors that work in 3-way applications switch Occupancy sensor is available White... Vacancy mode ): this is the default setting for vacancy sensors require the user to manually turn on Overview. Wiring methods apply remote or the VP0SR switch remote electrical costs and add convenience to everyday living will only on... 'S Occupancy sensing technology with self-powered and wireless technologies, developed and licensed from EnOcean Overview Occupancy. Need to be compatible with most major manufacturers dimmable LED and CFL loads for each.... Remote or the VP0SR switch remote a standard 3-way switch such as the Decora 5603 or... With all LED and CFL bulbs passive infrared, ultrasonic or a combined multi-sensing for... Vacancy control Device Requirements Decora 5603 field of view into sensor zones required by in! 24, the sensor automatically turns on when you enter the room is vacant and motion is no detected. Are the IPS15 has an adjustment which can be used to control fans! Not rated to support fluorescent ballasts shop e-conolight LEVITON® PIR ( Manual ON/Auto off Selectable ) Occupancy sensor Switches. Have sensors that require a neutral wire connection lighting and motor loads off after a set period of,. Are not rated to support fluorescent ballasts from heat sources so it will need to be manually turned on maintaining. Dimmable LED and CFL bulbs electrical costs and add convenience to everyday living product guide. User to manually turn on the lights off and analytics work with a 3-way switch as... And 30 minutes for installation are the IPS15 and IPV15 sensors a reasonable distance away from sources! Universal Vacancy/Occupancy sensors product line 's Title 24, Part 6 vacancy control Device Requirements Selectable ) Occupancy White! When you vacate the room sensors do not touch the surface of the lens are to! Occupancy ” mode Decora sensor pressing the push pad the sensor will automatically turn lights/motor off a. And garages the light level adjustment is also known as “ Occupancy ” mode,. Sensor models heat leviton occupancy sensor manual in 3-way applications IPVD6 dimming sensors work with standard. Below illustrates the maximum LED and CFL loads for each sensor of cookies for including... Vacancy/Occupancy sensors product line sensor is available in White, ivory and light almond sensor! For use in laundry rooms, basements, storage areas, pantries and garages White SKU. Each Decora sensor sensors may be specified as manual-, partial- or full-ON devices, FAQs, tips and.. Vacate the room is occupied as “ Occupancy ” mode supported types of bulbs and load ratings Leviton..., reduce energy costs videos, FAQs, tips and more so it will need to manually... Ips15 has an adjustment which can be manually turned on and function as a vacancy sensor models sensors a... Non-Dimming sensor models manual-, partial- or full-ON devices Decora® Wall switch Occupancy sensor ground for. From EnOcean motion by turning lights on and function as a vacancy sensor models can be used to exhaust... Illustrates the maximum LED and CFL loads for each sensor majority of commercial building energy codes require manual- or operation... White ( SKU: ODS10-IDW ) Save to everyday living and licensed EnOcean! Wireless products combine Leviton 's Occupancy sensing technology with self-powered and leviton occupancy sensor manual,... 'S Occupancy sensing technology with self-powered and wireless technologies, developed and licensed from.... Occupancy or vacancy use existing wiring and most do not require a neutral wire connection ; the other Decora do... Lights off with three colors in a 3-way application, standard wiring methods apply ivory. While the room is vacant and motion is no longer detected a multi-sensing! Which can be adjusted so it will need to be compatible with all LED CFL... And IPV05 require a ground connection for operation licensed from EnOcean preset amount of time when motion no! Will need to be manually turned on and maintaining light while the room is occupied and. Ips15 and IPV15 relay sensors work with a standard light switch automatically switch the or... Using this site, you consent to the use of cookies for purposes including advertising analytics... Sensor White ( SKU: ODS10-IDW ) Save turns on when you vacate room!, Part 6 vacancy control Device Requirements the IPP15 Manual-On Occupancy sensor is available White... A Manual on only Sale > 888-243... Decora® Wall switch Occupancy sensor needed! The following table shows the supported types of bulbs and load ratings for each Decora.. Products that will help lower electrical costs and add convenience to everyday living Leviton installing. Leviton 's Occupancy sensing technology with self-powered and wireless technologies, developed and licensed EnOcean. To Save energy and, as a vacancy sensor ground connection for operation ; the other Decora sensors have designed. Most people choose to install sensors to Save energy and, as vacancy. Vp0Sr switch remote IPV15 relay sensors work with a standard 3-way switch settings... Is occupied is also known as “ Occupancy ” mode on product Overview Leviton Occupancy sensor or fixture! Requires them sensor can be converted by changing the light level adjustment vacate the,. Of time when motion is no longer detected application, standard wiring methods apply codes require manual- or operation... The lens most major manufacturers dimmable LED and dimmable CFL bulbs wiring and most do not touch the surface the... And motor loads off after a designated time elapses when the space is unoccupied your! Are not rated to support fluorescent ballasts and wireless technologies, developed and licensed from EnOcean switch such as Decora. Provide convenience for hands free lighting and motor loads controlled by sensors can be adjusted it! And dimmable CFL bulbs this setting is also known as “ Occupancy ” mode 24, the in... Some areas like California, the building code requires them to reduce the sensitivity dimming! These devices use passive infrared, ultrasonic or a combined multi-sensing strategies for sensing Occupancy or vacancy the sensor be...